CTSHL Series: Advanced Harmonics and Flicker Test Systems

Complete Test Solution
Conducted Emissions Testing

  • IEC 61000-3-2
  • IEC 61000-3-3
  • IEC 61000-3-11
  • IEC 61000-3-12

Immunity Testing Options available
User Friendly Software Interface
Includes the programmable AC source and reference impedance

 
  • Overview
  • Manuals
  • Data Sheets
  • Software
  • Other
  • Part No.
In today's rapidly evolving global market, electronic products must meet stringent international regulatory requirements for emissions and immunity. This is especially crucial for products sold in Europe and an increasing number of countries in Asia. The California Instruments CTSHL System offers a cost-effective solution for verifying high power product compliance with various AC/DC-harmonized test standards. Building on the proven capabilities of the California Instruments CTS Series, the CTSHL system is trusted by EMC labs worldwide for its reliability and advanced features.

Supported Test Standards


Supported Version
Title Edition
IEC 61000-3-2:2018+AMD1:2020 CSV Limits for harmonic current emissions (equipment ≤16 A per phase) 5.1
IEC 61000-3-3:2013+AMD1:2017+AMD2: 2021 CSV Limitation of voltage changes, voltage fluctuations and flicker (equipment ≤16 A per phase) 3.2
IEC 61000-3-11:2017 RLV Limitation of voltage changes, voltage fluctuations and flicker (equipment ≤75 A per phase) 2.0
IEC 61000-3-12:2011+AMD1:2021 CSV
Limits for harmonic current emissions (equipment ≤16 A per phase) 2.1
IEC 61000-4-11:2020 RLV [1] Voltage dips, short interruptions and voltage variations immunity tests (equipment ≤16 A per phase) 3.0
IEC 61000-4-13:2002+AMD1:2009+AMD2: 2015 CSV Harmonics and interharmonics including mains signalling at a.c. power port, low frequency immunity tests 1.2
IEC 61000-4-14:1999+AMD1:2001+AMD2: 2009 CSV
Voltage fluctuation immunity test for equipment with input current not exceeding 16 A per phase
1.2
IEC 61000-4-17:1999+AMD1:2001+AMD2: 2008 CSV Ripple on d.c. input power port immunity test 1.2
IEC 61000-4-28:1999+AMD1:2001+AMD2: 2009 CSV Variation of power frequency, immunity test for equipment with input current not exceeding 16 A per phase 1.2
IEC 61000-4-29:2000 [1] Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
1.0
Note [1]: Pre-compliance

Key Features of the CTSHL Series

  • The Direct PC bus access data acquisition system provides the required sampling rate and resolution to meet IEC 61000-4-7 measurement requirements and supports high-speed data transfers.
  • PC-based Harmonic and Flicker test software provides real-time full-color data display updates and continuous PASS/FAIL monitoring.
  • Automatic calculation of the maximum permissible system impedance Zsys, using the Zref and measured Flicker parameters, as required per EN/IEC 61000-3-11.
  • Intuitive operating software provides IEC test setup, data analysis, display, with test reports in and MS Word format.
  • High resolution, no gap acquisition data storage to ensure that all data can be streamed to disk (in ASCII format if needed) for later review and replay of the actual test.
  • Single Step and Fast playback mode of test results.


AC Power Source

The California Instruments CTSHL is designed to work seamlessly with either Sequoia or Tahoe Series AC/DC power sources. These power sources provide high current capabilities, offering up to 125 ARMS per phase for rigorous compliance testing. Both the Sequoia and Tahoe Series AC sources feature advanced arbitrary waveform generation, precision measurements, and waveform analysis capabilities, making them versatile additions to any test resource portfolio.

Refer to the Sequoia and Tahoe Series data sheets for detailed information on their capabilities and features.

The Sequoia and Tahoe Series not only support high power harmonics and flicker emissions tests but can also be used for a range of IEC 61000-4 AC immunity standards (certain options may be required, see ordering information for details).

High-Speed Direct PC Data Acquisition

A high-speed digital signal processor-based data acquisition system is used to implement the required IEC compliance measurement system. Direct access to the PC bus ensures a much higher data throughput capability than typically found in single-box IEC test systems that use the IEEE- 488 instrumentation bus to communicate with the PC. This architecture offers several advantages, not the least of which is the ability to support future versions of test standards by merely installing new PC software. This greatly reduces the risk of product obsolescence as test standards evolve. Furthermore, since the data is streamed to a hard disk in real-time, a complete data record is created each time, which may be used for audit purposes, further analysis or to prove compliance with the test standard. A special signal conditioning and isolation unit (PACS-3-75) is used to provide a quick and easy connection between the AC source output and the Equipment Under Test. This unit provides the required isolation, signal conditioning, and anti-alias filtering for the measurement system. The equipment under test is wired to a rear panel-mounted terminal block.

Comprehensive Harmonics Analyzer

A key part of the CTSHL system is the IEC-compliant power analyzer which provides detailed information on both voltage and current. Measurements of both harmonics and inter-harmonics are made in real-time with no measurement gaps to fully conform to the latest revision of the IEC 61000-4-7 test standard. 

AC source voltage and EUT power are monitored continuously during the entire test. Voltage distortion and current harmonic data are checked against IEC class limits for pass or fail detection. Comprehensive test reports can be generated easily. Test limits are retained in a password-protected database and can be updated if needed in the future without the need to change software. Other software changes because of changing IEC harmonics standards can be accomplished by simply installing new PC software. No harmonics testing software resides.

IEC-Compliant Flicker Reference Impedance

The IEC 60725 compliant reference impedance, capable of handling 75A RMS per phase, is housed in a 43” cabinet. This lumped impedance is designed for testing to the IEC 61000-3-11 Flicker standard. For IEC 61000-3-3 low power Flicker testing (< 16 ARMS), the OMNI-3-37 is used instead, and is mounted in a similar 43” cabinet. The current system includes both the OMNI 3-37 and the OMNI 3-75, allowing for comprehensive testing to both standards. A quick connect scheme is used to switch between the two impedances, providing flexibility and ease of use in a single, combined system.

Compliant Flicker Meter

The IEC 60868-compliant Flicker meter, consisting of the Power Analysis Conditioning System (PACS) and the computer-mounted DSP is an integral part of this cabinet-mounted system.
CTSH User Manual : Rev K
CTSL User Manual : Rev K
Title
Document
Download
CTSH User Manual : Rev K
DocumentMX CTSH User Manual : Rev K
Download Download
CTSL User Manual : Rev K
DocumentMX CTSL User Manual : Rev K
Download Download
CTSHL Data Sheet
Title
Document
Download
CTSHL Data Sheet
DocumentCTSHL Data Sheet
Download Download
CTSH V2.33, Windows XP/7/10/11 32/64-Bit
CTSL V2.34, Windows XP/7/10/11 32/64-Bit
Title
Document
Download
CTSH V2.33, Windows XP/7/10/11 32/64-Bit
DocumentCTSH V2.33, Windows XP/7/10/11 32/64-Bit
Download Download
CTSL V2.34, Windows XP/7/10/11 32/64-Bit
DocumentCTSL V2.34, Windows XP/7/10/11 32/64-Bit
Download Download
CTS Compliance Test System Tutorial
Title
Document
Download
CTS Compliance Test System Tutorial
DocumentCTS Compliance Test System Tutorial
Download Download
For specifications of the AC/DC power source, refer to the Sequoia or Tahoe Series data sheet. The CTSHL system requires a Sequoia or Tahoe Series AC Source to function. The CTSHL system is an option for the Sequoia or Tahoe power source.
Add the CTSHL configuration option to the Sequoia or Tahoe part number string
-CTSHL
 

Complete Harmonics and Flicker Test System including:

  • PACS-3-75 Measurement system. Mounted in OMNI-3-75 cabinet.
  • OMNI-3-37MX Three phase Lumped impedance for IEC 61000-3-3 Flicker
  • OMNI-3-75 Three phase Lumped impedance cabinet for IEC 61000-3-11 Flicker
  • CIC652 CTSL Software for IEC 61000-3-2 (Harmonics and IEC 61000-3-3 (Flicker) testing. (P/N CIC652)
  • CIC651 CTSH Software for IEC 61000-3-12 (Harmonics and IEC 61000-3-11 (Flicker) testing. (P/N CIC651)
  • Rackmount PC with integrated PCIe DAQ card
  • Rackmount Console - Integrated rack keyboard, monitor
PC Requirements
CPU Pentium 4, 1.2 GHz clock or faster.
RAM 256 Mbytes or more.
Hard Disk 20 Gbytes or more. 20 Mbytes required for program storage.
Display Color SVGA Monitor
Slots Available PCI slot for A/D card.
Software MS Word, Windows
IEEE-488 For control of the power source, a National Instruments IEEE bus controller and available PC slot or RS232 port are required.
California Instruments will quote a PC as part of the system on request. Contact factory for details.
Other Relevant AC Source Options:
IEC
  • EN/IEC 61000-4-11 Voltage Dips and Interruptions test option (pre-compliance)
  • EN/IEC 61000-4-13 Harmonics and Inter- Harmonics test option.
AVSTD

Avionics Test Suite, including:

  • RTCA-DO 160G/EUROCAE
  • MIL-STD 704 A-F
  • ABD100.1.8 D&E
  • A350
AVALL

Expanded Avionics Test Suite, including

  • AVSTD
  • B787
  • AMD
MIL1399
MIL-STD1399 Ship Power Quality.
PC Options:
CIC-PC Suitable Pentium class PC with preinstalled CTS and MXGUI software. Includes Case, keyboard, mouse, Windows and MS Word.
CIC-PCX Adds 15 inch monitor and printer to CIC-PC.
Accessories
CI400PCI Spare PCI A/D Card
CI68C Spare 37 pin signal interface cable for PCI.