Overview
-
Manuals
-
Data Sheets
-
Software
-
Other
-
Part No.
Meet the CTS 4.0 Series, your ultimate solution for seamless compliance with EN IEC 61000-3-2 (Harmonics), EN IEC 61000-3-3 (Flicker), and various EN IEC 61000-4 AC and DC immunity tests. Designed for efficiency and reliability, this turn-key system ensures your products meet the highest standards. It includes an AC power source, a power analysis conditioning system (PACS), and a PC-based data acquisition system, compliant with IEC 61000-4-7. The Windows™-based CTS software performs IEC tests and generates detailed reports, with test data stored on disk for post-test analysis.
The IEC Compliance Test Systems - CTS Series implements several EMC-conducted emissions and immunity standards and provides a software-only upgrade path for future standard changes.
Alongside our CTSHL Series, the California Instruments CTS 4.0 is trusted by EMC labs worldwide for its reliability and advanced features.
The IEC Compliance Test Systems - CTS Series implements several EMC-conducted emissions and immunity standards and provides a software-only upgrade path for future standard changes.
Alongside our CTSHL Series, the California Instruments CTS 4.0 is trusted by EMC labs worldwide for its reliability and advanced features.
Covered EN IEC Standards
The CTS 4.0 Series supports the following EN IEC standards for compliance testing:| Supported Version | Title | Edition |
| IEC 61000-3-2:2018+AMD1:2020 CSV | Limits for harmonic current emissions (equipment ≤16 A per phase) | 5.1 |
| IEC 61000-3-3:2013+AMD1:2017+AMD2: 2021 CSV |
Limitation of voltage changes, voltage fluctuations and flicker (equipment ≤16 A per phase) |
3.2 |
| IEC 61000-4-11:2020 RLV [1] |
Voltage dips, short interruptions and voltage variations immunity tests (equipment ≤16 A per phase) | 3.0 |
| IEC 61000-4-13:2002+AMD1:2009+AMD2: 2015 CSV | Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity tests | 1.2 |
| IEC 61000-4-14:1999+AMD1:2001+AMD2: 2009 CSV | Voltage fluctuation immunity test for equipment with input current not exceeding 16 A per phase | 1.2 |
| IEC 61000-4-17:1999+AMD1:2001+AMD2: 2008 CSV | Ripple on DC input power port immunity test | 1.2 |
| IEC 61000-4-28:1999+AMD1:2001+AMD2: 2009 CSV | Variation of power frequency, immunity test for equipment with input current not exceeding 16 A per phase | 1.2 |
| IEC 61000-4-29:2000 [2] | Voltage dips, short interruptions and voltage variations on DC input power port immunity tests | 1.0 |
| Note [1]: Full compliance with EOS option; Note [2]: Pre-compliance |
||
EN 61000-3-2 Harmonics
Full compliance testing for single-phase and three-phase current harmonics emissions of class A, B, C, and D products is supported. Supports IEC 61000-3-2:2018 + AMD1:2020 CSV.EN 61000-3-3 Flicker
Displays Flicker PST & PLT results in real-time, eliminating the need to wait for test completion to determine if the EUT passed or failed. Supports both programmable and lumped reference impedance methods for flicker testing, in accordance with IEC 61000-3-3:2013/AMD2:2021 CSV.EN 61000-4-11 Voltage Dips, Interruptions, and Variations
Offers pre-compliance Voltage Dips and Interruptions on most CTS systems. For full compliance, add the Electronic Output Switch (option -EOS1 or -EOS3) to any iX-based IEC Compliance Test System. Supports IEC 61000-4-11:2004-03."EN 61000-4-13 Harmonics and Interharmonics
Supports testing to the EN 61000-4-13 Interharmonics standard on all iX Series-based CTS systems with the -413 option. Complies with IEC 61000-4-13:2009-05.Other EN 61000-4 Immunity Tests
Supports additional immunity test standards on all iX-based IEC Compliance Test Systems.Configurations
Available in both single-phase (3000 VA to 5000 VA) and three-phase (15 kVA or 18.5 A per phase at 230 V) configurations. Single-phase 5001iX-CTS systems can be upgraded to three-phase if needed. Measurement-only versions (100-CTS and 300-CTS) can be added to an existing California Instruments power source.Key Features of CTS 4.0
- Comprehensive Test Solutions - Our CTS 4.0 Series offers complete test solutions for emissions and immunity compliance testing of AC and DC power products, ensuring your products are ready for global markets.
- Single & Three Phase Operation - Offers flexibility
- Direct PC Bus Access - Provides high sampling rate and resolution for accurate measurements and high-speed data transfers
- PC-Based Harmonic & Flicker Testing - Provides real-time full-color data display updates and continuous PASS/FAIL monitoring
- Supports Global Standards - Supports European and Japanese standards
- Easy To Use Interface - Provides IEC test setup, data analysis, display, MS Word test reports, and data files generated in MS Excel format
- High Resolution - Data storage to disk for post-acquisition analysis and reporting
- Single Step - Single Step and Fast Forward replay of recorded test data at 200 mSec
Don't leave compliance to chance. Discover the reliability and efficiency of the CTS 4.0 Series. Reach out to us now for more information. Our experts are standing by to support your Compliance Test needs!
| Standard controller versions with single voltage range | |||||
|---|---|---|---|---|---|
| Single Phase Systems | |||||
| Model | VA Power | AC Source | EN61000-4 | PACS Model | |
| 100-CTS | AC Line | None | - | PACS-1 | |
| 1251RP-CTS | 1250 VA | 1251RP | - | PACS-1RP | |
| 3001iX-CTS | 3000 VA | 3001iX | ■ | PACS-1 | |
| 5001iX-CTS (-400) | 5000 VA | 5001iX (-400) | ■ | PACS-1 | |
| 10001iX-CTS (-400) | 10000 VA | 10001iX (-400) | ■ | PACS-1 | |
| Three Phase Systems | |||||
| 300-CTS-75 | AC Line | none | - | PACS-3-75 | |
| 15003iX-CTS (-400) | 15000 VA | 15003iX (-400) | ■ | PACS-3 | |
| MX45-3Pi-CTS | 45000 VA | MX45-3Pi | ■ | PACS-3-75 | |
| PC Requirements | |
|---|---|
| CPU | Pentium / Athlon 2.0 GHz or faster. |
| RAM | 1 GBytes or more. |
| Hard Disk | 10 Gbytes or more. 30 Mbytes required for program storage. |
| Display | Color SVGA/XGA Monitor |
| Slots | Available PCI slot for A/D card. |
| Software | MS Word, Windows |
| IEEE-488 | For control of the power source, a NI IEEE-488 bus controller and available PC slot, RS232 or USB port are required. |
| California Instruments will quote a PC as part of the system on request. Contact factory for details. |
|
| Included with each CTS system | |
| -PCI | CI400PCI PCI Bus, 16 bit A/D Card. |
| iX Series based CTS Options | |
| -LR1 | Lumped Reference Impedance for 3/5001iX-CTS configurations. Installed in PACS-1. |
| -LR2¹ | Lumped Reference Impedance for 10001iX-CTS configuration. |
| -LR3² | Lumped Reference Impedance for 15003iX-CTS. (OMNI- 3-18i) |
| -OMNI-3-75 | Lumped Reference Impedance for MX45-CTS. (OMNI-3- 75i - 3 phase) |
| -LR5 | Japanese Lumped Reference Impedance (100 V) for single phase systems. (OMNI-1-37iJ) |
| -EOS1 | EN/IEC 61000-4-11 AC source compliance Electronic Output Switch for single phase CTS Systems. |
| -EOS3 | EN/IEC 61000-4-11 AC source compliance Electronic Output Switch for 15003iX System. |
| -411 | EN/IEC 61000-4-11 Voltage Dips and Interruptions test option. (included with -EOS options) |
| -413 | EN/IEC 61000-4-13 Harmonics and Inter-Harmonics test option. |
| -LNS | Internal AC Line Sync. (iX Series only) |
| -XLS | External AC Line Sync. (iX Series only) |
| General Options | |
| C | Cabinet. System installed in 19” instrument rack. Highly recommended for all three phase systems. Prefix ‘C’ to standard model number to order. |
| CIC-PC | Suitable PC with pre-installed CTS and CIGUI software. Includes Case, keyboard, mouse, Windows and MS Word. |
| CIC-PCX | Adds 17 inch monitor and printer to CIC-PC. |
| -RMS | Rack mount slides. |
| Accessories | |
| CI400PCI | Spare PCI A/D Card |
| CI68C | Spare 37 pin signal interface cable for PCI. |
|
Higher Power Systems Note 2: Option -LR3 is recommended for 15003iX-CTS systems. See App note 119 for details. |
|