PLA

Model: PLA
Voltage10–1200 Vdc
Current10–1500 Adc
Power: 800 W–7.5 kW
Overview: Air-cooled programmable DC electronic load

Request A Quote

  • Overview
  • Manuals
  • Data Sheets
Traditional DC Electronic Load Solutions are bulky and large in size. Most are offered with standard voltage, current and power ratings. In the ATE world, rack space is a highly coveted asset and application demands are constantly diversifying with new technology development.

AMETEK Programmable Power's PLA Series of “Air-cooled” DC Electronic Electronic Loads offers the industry’s smallest footprint, the highest power density and current rating, along with the broadest selection of high voltage models on the market. PLA models are capable of being custom-tailored to meet your application requirements.

Features And Benefits

Closed-case Calibration

With the eLoad line, there’s no longer a need to send your electronic load back to the factory for calibration or remove dozens of screws to reach a potentiometer. Simply follow the calibration routine from the front panel and you should be back up and running in a very short period of time (some electronic test equipment needed). This will virtually eliminate downtime and eradicate the annual cost associated with shipping your eLoad back to the factory for calibration.

Individual FET Protection
To ensure the reliability of the PLA Series, the design includes individual FET protection. A programmable electronic load may contain many FETs in parallel, which can create a cascading failure if one of them was to short out. The PLA eLoad programmable electronic load design isolates failures so other components will not be affected or stressed, increasing the system’s level of protection against catastrophic failure. With individual FET protection, the MTTR is reduced and the electronic load quickly returns to full operation.

Ultra-low Voltage Operation
The PLA design allows the programmable electronic load to operate at voltage levels approaching .1V. They will typically dissipate full rated current below 1% of their maximum rated voltage. For example, a 60V unit designed to dissipate1500A will allow the user to operate at .6V and still dissipate the full amount.
img1
PLA-PLW Operation Manual M470039-01 Rev F
img1
PLA-PLW Programming Manual Rev C
Title
Document
Download
PLA-PLW Operation Manual M470039-01 Rev F
DocumentPLA-PLW Operation Manual M470039-01 Rev F
PLA-PLW Programming Manual Rev C
DocumentPLA-PLW Programming Manual Rev C
img1
PLA Cut Sheet
img1
PLA Datasheet
Title
Document
Download
PLA Cut Sheet
DocumentPLA Cut Sheet
PLA Datasheet
DocumentPLA Datasheet

* Required entries
 Required for USA and Canada
Note:
If you experience any difficulty submitting this form, contact: webmaster@zygo.com

** You may withdraw this consent at any time using the "unsubscribe" link at the bottom of any page on this web site.
X
By continuing to use this site, you agree to our Privacy Policy.
OK