| Output : Voltage and Current |
|
| Model |
Output
Voltage |
Output
Current |
Output
Power |
Outputs |
| XPL 18-3 |
0-18 V |
0-3.3 A |
60 W |
1 |
| XPL 30-1 |
0-30 V |
0-1 A |
30 W |
1 |
| XPL 30-2 |
0-30 V |
0-2 A |
60 W |
1 |
| XPL 30-2D |
0-30 V |
0-2 A |
120 W |
2 |
| XPL 30-2T |
0-30 V |
0-2 A |
125 W |
3 |
| XPL 56-1 |
0-56 V |
0-1.1 A |
60 W |
1 |
|
 |
|
 |
|
| Feature |
Description |
| Operating Mode |
Constant voltage or constant current with automatic cross-over and indication |
| Voltage Setting |
By coarse and fine controls |
| Current Setting |
By single logarithmic control |
| Line Regulation |
< 0.01% of max. output for a 10% line voltage change |
| Load Regulation |
< 0.01% of max. output for a 90% load change |
| Output Impedance |
Typically < 5 mΩ in constant voltge mode. Typically > 50 kΩ in constant current mode |
| Ripple & Noise |
(20 MHz) Typically < 1 mVrms (CV mode) |
| Transient Response |
< 20 μs to within 50 mV of set level for 90% load change |
| Temperature Coefficient |
Typically < 100 ppm/°C |
| Output Protection |
Outputs will withstand forward voltages of up to 20 V above the rated output voltage. Reverse protection by diode clamp
for current up to 3 A. |
| Status Indication |
Ouptut ON lamps. Constant current mode lamps |
| Output Switch |
Electronic. Preset voltage and current displayed when output is off |
| Output Terminals |
4 mm terminals on 19 mm (0.75”) pitch |
| Meter Resolutions |
100 mV, 10 mA |
| Meter Accuracy Voltage |
0.3% ±1 digit |
| Meter Accuracy Current |
0.6% ±1 digit |
| AC Input |
115 V or 230 Vac ±10% (adjustable internally, option HV for factory set 230 Vac input) Installation Category ll |
| Power Consumption |
85 VA (XPL 30-1)
160 VA (XPL 30-2, XPL 18-3, XPL 56-1)
320 VA (XPL 30-2D, XPL 30-2T) |
| Operating Range |
5 to 40°C , 20% to 80% RH |
| Storage Range |
- 40 to 70°C |
| Environmental |
Indoor use at altitudes to 2000 m, Pollution Degree 2 |
| Cooling |
Silent fan-less convection cooling |
| Safety |
Complies with EN61010-1 |
| EMC |
Complies with EN61326 |
Dimensions
(H x W x D) |
6.3 x 5.5 x 11.6” (160 x 140 x 295 mm) (XPL 30-1, XPL30-2, XPL 18-3, XPL 56-1)
6.3 x 10.2 x 11.6” (160 x 260 x 295 mm) (XPL 30-2D, XPL 30-2T) |
| Weight |
7.5 lb (3.4 kg) (XPL 30-1)
9.7 lb (4.4 kg) (XPL30-2, XPL 18-3 XPL 56-1)
16.5 lb (7.5 kg) (XPL 30-2D, XPL 30-2T) |
| Approvals |
CE-marked units meet: EN61010-1 and EN61326 |
|
 |
|
 |
|
 |
|

|
 |
 |