AMETEK Programmable Power
Programmable Power Products
Elgar, Sorensen and California Instruments Products
DC ProductsBench Products AC Products Modular AC/DC Electronic Loads Custom Solutions
Overview Features Specifications Technical Diagrams Downloads Get a Quote
Sorensen : XDL Series : Specifications
Output : Voltage and Current
Model Output Range Output Range 2 Output Range 3
35-5 1 0-35 V, 0-3 A 0-15 V, 0-5 A 0-35 V, 0-500.0 mA
35-5T 0-35 V, 0-3 A 0-15 V, 0-5 A 0-35 V, 0-500.0 mA
35-5P 0-35 V, 0-3 A 0-15 V, 0-5 A 0-35 V, 0-500.0 mA
35-5TP 0-35 V, 0-3 A 0-15 V, 0-5 A 0-35 V, 0-500.0 mA
56-4 0-56 V, 0-2 A 0-25 V, 0-4 A 0-56 V, 0-500.0 mA
56-4P 0-56 V, 0-2 A 0-25 V, 0-4 A 0-56 V, 0-500.0 mA
Model Outputs Output Power Interface (GPIB/RS-232/USB)
35-5 1 105 W No
35-5T 3 215 W No
35-5P 1 105 W Yes
35-5TP 3 215 W Yes
56-4 1 112 W No
56-4P 1 112 W Yes
Voltage Setting By floating point numeric entry or rotary jog wheel; resolution 1mV
Current Setting By floating point numeric entry or rotary jog wheel; resolution 1mA or 0.1mA depending on range
Setting Accuracy Voltage 0.03% ± 5 mV. Current 0.2% ± 5 mA, 0.5 mA
Output Mode Operation in constant voltage or constant current modes with automatic cross-over and mode indication by LEDs.
DC Output Switch Sets output voltage and current levels to zero when Off.
Output Terminals 4 mm terminals on 19 mm (0.75”) spacing
Load Regulation Voltage: < 0.01% + 2 mV Current: < 0.01% + 250 μA; < 0.01% + 50 μA on 500 mA range (measured at output terminals using remote sense)
Line Regulation Voltage: < 0.01% + 2 mV for 10% line change Current: < 0.01% + 250 μA; < 0.01% + 50 μA on 500 mA range
Ripple and Noise Typically < 0.35% Vrms 2 mVp-p CV mode, and < 0.2 mArms,
< 20 μArms (500 mA range) CI mode
Transient Response 50 μs to within 15 mV of set level for a change in load current from full load to half load or vice versa
Temperature Coefficient <± (50 ppm + 0.5 mV) / °C (voltage)
Remote Sense Eliminates up to 0.5 V drop per lead. Remote sense operation selected from front panel and indicated by LED
Sense Terminals Recessed sprung sockets for direct insertion of wires. Duplicated on rear terminal block (P versions only)
 
New Expanded AC Product Line Featuring California Instruments
   
Product Configurator
DC Electronic Loads
DC Modular Supply
Discontinued Products
Product Support
Contact Sales

General Specifications
Operational AC Input Voltage 115 V or 230 V ± 10% (adjustable internally, option HV for factory set 230 Vac input), 50/60 Hz. Installation Category II
Operating Temperature Range 5 to 40°C, 20% to 80% RH
Storage Temperature Range - 40 to 70°C
Dimensions (H x W x D) 6.3 x 5.5 x 11.4” (160 x 140 x 290 mm) (XDL 35-5, XDL 35-5P, XDL 56-4, XDL 56-4P),
6.3 x 11.0 x 11.4” (160 x 280 x 290 mm) (XDL 35-5T, XDL 35-5TP)
Weight 11.9 lb (5.4 kg) (XDL 35-5, XDL 56-4)
12.1 lb (5.5 kg) (XDL 35-5P, XDL 56-4P)
23.1 lb (10.5 kg) (XDL 35-5T)
23.3 lb (10.6 kg) (XDL 35-5TP)
Benchtop Operation Folding legs are incorporated that can be used to angle the front panel upwards when required
Rack Mount Operation 19-inch 4U mount for up to three single output units or one triple, plus one single Blanking plates available for unused sections
Approvals CE-marked units meet: EN61010-1 and EN61326
Specifications subject to change without notice.