Power Ten P63 : Specifications
Common
Regulation Line: For input voltage variation over the AC input voltage range, with constant rated load.
Load: For 0-100% load variation, with constant nominal line voltage.
Voltage: 0.1% of maximum rated output
Current: 0.5% of maximum rated output
Power Factor 0.72 min.
Series Operation Up to 2 units (See Output Float Voltage)
Transient Response A 30% current step load will recover to within ±2% of set voltage within 10 msec.
Stability ±0.05% of set point per 8 hours after 30 minutes warm-up at fixed line, load and temperature.
Temperature Coefficient 0.02%/°C of rated output voltage
0.03%/°C of rated output current
Change in output per °C change in ambient temperature, with constant line and load
Operating Temperature 0 to +50° C, No derating
Storage Temperature -20 to +70°C
Cooling Internal fans
Controls (Front Panel) On/Off switch, DC volts adjust, DC amps adjust, OVP preset adjust (limit set)
Meters/Indicators LCD DC voltmeter, ammeter and OVP limit set. LED indicators for voltage mode, current mode. OVP fault and fault
Built-In Protection Over Voltage, Current limit Fold back, Over Temperature, Brown Out, Turn On Surge Limit, Slow Start
Remote Control/Monitor
(Rear Panel)
On/Off control via contact closure, 6-120 VDC, TTL or CMOS switch, output voltage and current monitor, OVP limit set, summary fault status on P60 Series.
Remote Programming   Voltage (0 to 100%) Current (0 to 100%)
Resistive 0-5K ohms 0-5K ohms
Voltage 0-5 VDC or 10 VDC 0-5 VDC or 10 VDC
Remote Sensing Terminals provided to sense output voltage at load. Line drop subtracts from the maximum available output voltage at full rated power.
Operational Features Master/Slave, Series, Parallel
Primary Power (Standard) P63C and P66C
190-253 VAC2
Regulatory Certified to UL/CSA 61010 and IEC/EN 61010-1 CE Compliant (LVD and EMC directive)
Input
Input Voltage 190-253 VAC, 47-63 Hz (Standard)
360-440 VAC, 47-63 Hz (Option)
432-528 VAC, 47-63 Hz (Option)
Input Current
@ 208 VAC (Typical)
At 3.3 kW Output: 15 A
At 6.6 kW Output: 28 A
At 10.0 kW Output: 41 A
Operates from Delta or Wye Source
Physical
Dimensions 19” (W) X 5.25” (H) X 22” (D)
Weight 3.3 kW: 40 Lbs.
6.6 kW: 60 Lbs.
10.0 kW: 80 Lbs.
Interface
AC Input Interface 3 wire + GND (#10-32 threaded studs) (208 VAC)
3 wire + GND (#1/4-20 threaded studs) (208 VAC) Bus bars with 0.390” interface holes for output ≤50 VDC.
Control/Monitor
Interface

DB 25-pin female connector

Output: Voltage and Current Ranges
Model Output DC Output
p-p Ripple
Volts Amps
P63C-5500 0-5 500 50 mV
P63C-51000 0-5 1000 50 mV
P63C-51500 0-5 1500 50 mV
P63C-8400 0-8 400 50 mV
P63C-8800 0-8 800 50 mV
P63C-81200 0-8 1200 50 mV
P63C-10330 0-10 330 50 mV
P63C-10660 0-10 660 50 mV
P63C-101000 0-10 1000 50 mV
P63C-12.5265 0-12.5 265 50 mV
P63C-12.5530 0-12.5 530 50 mV
P63C-12.5800 0-12.5 800 50 mV
P63C-15220 0-15 220 50 mV
P63C-15440 0-15 440 50 mV
P63C-15660 0-15 660 50 mV
P63C-20166 0-20 166 75 mV
P63C-20330 0-20 330 75 mV
P63C-20500 0-20 500 75 mV
P63C-25134 0-25 132 75 mV
P63C-25265 0-25 265 75 mV
P63C-25400 0-25 400 75 mV
P63C-30110 0-30 110 75 mV
P63C-30220 0-30 220 75 mV
P63C-30330 0-30 330 75 mV
P63C-5066 0-50 66 75 mV
P63C-50133 0-50 133 75 mV
P63C-50200 0-50 200 75 mV
Remote Computer Programming Options
IEEE 488.2 and RS 232 Interface Option enables the power supply to be operated from a computer with full remote programming control and monitoring. The slave interface option allows multichannel control from a single bus address.
Programming Resolution Voltage: 0.03% of full scale
Current: 0.03% of full scale
Over voltage Protection: 0.03% of full scale
(full scale is 120% of maximum output voltage)
Programming Accuracy Voltage: ± (0.1% + 0.1% of maximum output voltage)
Current: ± (0.1% + 0.4% of maximum output voltage)*
Overvoltage Protection ± (0.5% + 0.5% of maximum output voltage)
Readback Resolution Voltage and Current: ± 0.03% of full scale
Readback Accuracy

Voltage: ± (0.1% + 0.15% of full scale output voltage)
Current: ± (0.1% + 0.4% of full scale output current)*

* After 30 minutes operation with fixed line, load and temperature.
Programming
Programmable Functions • Output Voltage and Current
• Soft Limits for Voltage and Current
• Over Voltage Protection
• Output Enable/Disable
• Maskable Fault Interrupt
• Hold and Trigger
Readback Functions • Actual Measured Voltage and Current
• Voltage and Current Settings
• Soft Voltage and Current Limits
• Over Voltage Protection Setting
• Status and Accumulated Status Registers
• Programming Error Codes
• Fault Codes
• Manufacturer, Power Supply Model and Firmware Version Identification